VLUCHEM IND is developing, manufacturing and distributing top-qualified testing instruments for rubber, plastics and other industries to our valuable customers. Manufacturing and guarantee to keep the top-quality of its products durability, Vluchem Ind is operating the strict quality and management system which will give the customer's satisfaction when our customers operate our products. As a manufacturer for innovative and material testing instrument industries, we bear the responsibility for quality assurance.
VLUCHEM IND is developing, manufacturing and distributing top-qualified testing instruments for rubber, plastics and other industries to our valuable customers. Manufacturing and guarantee to keep the top-quality of its products durability, Vluchem Ind is operating the strict quality and management system which will give the customer's satisfaction when our customers operate our products. As a manufacturer for innovative and material testing instrument industries, we bear the responsibility for quality assurance.
AUTO IRHD TESTER
The international hardness test is based on measurement of the penetration of a rigid ball into the rubber specimen. The hardness is obtained by the difference in penetration depth of a specified dimension ball under conditions of contact with a minor force and with a major force. The differential penetration is taken at a specified time and converted to a hardness scale value. It’s performed according to ASTM D1415, KS M ISO 48 and ISO 48.The Vluchem’s IRHD-Micro is a fully automatic instrument which is far from operator’s influences and rubber material, polymer such as o-ring, oil seal and various molded final goods.
AIR - 20M
Resolution - 0.1 IRHD
Min. Test Thickness - 1 mm
Data Excel Export Function
ERP System (Option)
Ce Certification
Test Method |
IRHD Micro |
Resolution |
0.1 IRHD |
Indenter |
Ø 0.397 |
Total force on ball |
153.3mN ± 1.0 |
Minor force |
8.3 mN ± 0.5 |
Major force |
145 mN ± 0.5 |
Force on foot |
235mN ± 30.0 |
Measuring range |
30 ~ 100 |
Power |
210~240V, single phase 50/60Hz |
Display |
Color LCD graphic |
Data Output |
Graph, Test results, Single test and multi test available |
Hardness trend graph, test results pass/fail |
|
Tolerance limits, Time, Data excel export function |
|
RS 232C Cable, 9600 Baud | |
Measuring Time | 30 ~ 999, Default 30 sec |
Dimension | 250 X 310 X 440 mm / 16 Kgs |
Universal Testing Machine
Vluchem electromechanical universal testing machines perform tensile, compression as basic test methods and other various tests are available in accordance with the test jigs. These instruments are available in a range of sized and maximum force capacities. From small, low force instruments to test paper, rubber, plastics and film industries, to large, high force instruments to test metal and parts in the auto vehicle industries and ship yard industries, Vluchem has suitable for related applications. It’s performed according to ASTM D412, ISO 37 and others. So many instruments have been installed, operated in quality control, research & development in firms and universities.
VT-200 | VT-1T | VT-10T | |
Force Capacity | 2kN | 10kN | 100kN |
Crosshead Speed | 1 ~ 750 mm/min | ||
Crosshead Stroke | 800mm or over | ||
Dimension | 500x450x1500mm | 600x550x1900mm | 700x550x1900 |
Weight | 50kg | 120kg | 150kg |
Oscillating Disk Rheometer
The Vluchem’s oscillating disk rheometer (ODR-10) for determining selected vulcanization characteristics of vulcanizable rubber compounds and measured according to ASTM D 2084, ISO 3417 and KS M 6687. ODR- 10 may be used for quality control in rubber m anufacturing processes, for research and development testing of raw-rubber compounded in an evaluation formulation, and for evaluating various raw materials used in preparing rubber compounds. The instrument is equipped with the highest torque measurement, reliability, along with stiff hardware, superior heater, temperature sensor, temperature controller and Vluchem’s own designed data acquisition device and software. Designed to be placed on a desk instrument and is supplied with the Vluchem’s own data analysis software for test management, data recording and printing, automated Pass/Fail testing as well as recall processing of historical data, also available an online upload software as an option.
Model | ODR-10 | |
International Standard | ASTM D 2084 ISO 3417 and KS M 6687 | |
Motor | Induction Motor | |
Rotor | Biconical Disk | |
Oscillation frequency | 1.67Hz | |
Oscillation angle | 1°, 3°, 5° Mechanically adjustable | |
Protection for operator | Before test chamber closing | |
Test chamber moving | By Pneumatic |
Rotor Motor Platen operation |
available by hardware |
|
Temperature control |
available by hardware & |
|
Temperature range |
microprocessor controlled |
|
Temp. Sensor Type |
PT 100 Ω |
|
Torque range |
0~ 200 dNm |
|
Calibration |
Calibration jig |
|
Data |
Torque [dNm, lbf.in] Temperature [°C] MH, ML Ts1, Ts2, Tc10(N), Tc50(N), Tc90(N) Automatic test results pass/fail function Trend graphs Tolerance limits by time and torque Data excel export function, Average, S-Dev ERP system upload - option |
|
Pneumatics |
min 4.5 bar/60 Psi |
|
Electrical |
200~230V, 3A, single phase, 50Hz/60Hz |
|
Emergency Button |
|
|
Dimension |
W615 X D685 X H1200 mm |
|
Weight |
160 kgs |
Moving Die Rheometer
The Vluchem’s moving die rheometer (MR-10) for determining selected vulcanization characteristics of vulcanizable rubber compounds using rotorless sealed torsion meter and measured according to ASTM D 5289, ISO 6502-3 and KS M ISO6502.
MR-10 may be used for quality control in rubber manufacturing processes, for research and development testing of raw-rubber compounded in an evaluation formulation, and for evaluating various raw materials used in preparing rubber compounds.
The instrument is equipped with the highest torque measurement, reliability, along with stiff hardware, superior heater, temperature sensor, temperature controller and Vluchem’s own designed data acquisition device and software.
Designed to be placed on a desk instrument and is supplied with the Vluchem’s own data analysis software for test management, data recording and printing, automated Pass/Fail testing as well as recall processing of historical data, also available an online upload software as an option.
Model | MR-10 |
International Standard | ASTM D 5289 ISO 6502 KS M ISO 6502 |
Motor | Induction Motor |
Die configuration | Biconical, closed die system, sealed |
Oscillation frequency | 1.67Hz |
Oscillation angle | 0.5°[Option]1°, 3°, 5° |
Protection for operator |
Before test chamber closing |
Test chamber moving |
By Pneumatic |
Motor Platen operation |
available by hardware |
Temperature control |
available by hardware & |
Temperature range |
microprocessor controlled |
Temp. Sensor Type |
PT 100 Ω |
Torque range |
0~ 200 dNm |
Calibration |
Calibration jig |
Data |
Torque[dNm, lbf.in] Temperature [°C] MH, ML Ts1, Ts2, Tc10(N), Tc50(N), Tc90(N) Automatic test results pass/fail function Trend graphs Tolerance limits by time and torque Data excel export function, Average, S-Dev |
Pneumatics |
min 4.5 bar/60 Psi |
Electrical |
200~230V, 3A, single phase, 50Hz/60Hz |
Emergency Button |
|
Dimension |
W615 X D685 X H1200 mm |
Weight |
160 kgs |
Auto Moving Die Rheometer
The Vluchem’s automatic moving die rheometer (AMR-10) for determining selected vulcanization characteristics of vulcanizable rubber compounds using rotorless sealed torsion meter and measured according to ASTM D 5289, ISO 6502-3 and KS M ISO6502.
MR-10 may be used for quality control in rubber manufacturing processes, for research and development testing of raw-rubber compounded in an evaluation formulation, and for evaluating various raw materials used in preparing rubber compounds.
The instrument is equipped with the highest torque measurement, reliability, along with stiff hardware, superior heater, temperature sensor, temperature controller and Vluchem’s own designed data acquisition device and software.
Designed to be placed on a desk instrument and is supplied with the Vluchem’s own data analysis software for test management, data recording and printing, automated Pass/Fail testing as well as recall processing of historical data, also available an online upload software as an option.
Automatic Sample supply device
Model | AMR-10 | |
International Standard | ASTM D 5289 ISO 6502 KS M ISO 6502 | |
Motor | Induction Motor | |
Die configuration | Biconical, closed die system, sealed | |
Oscillation frequency | 1.67Hz | |
Oscillation angle | 0.5°[Option]1°, 3°, 5° | |
Protection for operator | Before test chamber closing | |
Test chamber moving | By Pneumatic |
Motor Platen operation |
available by hardware |
||
Temperature control |
available by hardware & |
||
Temperature range |
microprocessor controlled |
||
Temp. Sensor Type |
PT 100 Ω |
||
Torque range |
0~ 200 dNm |
||
Calibration |
Calibration jig |
||
Data |
Torque[dNm, lbf.in] Temperature [°C] MH, ML Ts1, Ts2, Tc10(N), Tc50(N), Tc90(N) Data excel export function, Trend graphs Tolerance limits by time and torque Average, S-Dev |
||
Pneumatics |
min 4.5 bar/60 Psi |
||
Electrical |
200~230V, 3A, single phase, 50Hz/60Hz |
||
Emergency Button |
|
||
Dimension |
W1200 X D685 X H1200 mm |
||
Weight |
180 kgs |
|
|
Linear Automation |
AMR-10 [5 samples] |
Mooney Viscometer
The Vluchem’s Mooney Viscometer (MV-10) which measures the Mooney viscosity is defined as the shearing torque resisting rotation of a rotor embedded in rubber within a cylindrical cavity. At the end of a Mooney viscosity test, the rotation of the rotor is suddenly stopped and the rate of decrease of torque is monitored as a function of time. This is called stress relaxation. Characteristics of uncompounded or compounded rubbers and measured according to ASTM D 1646, ISO 289, KS M ISO 289-1, 2 and 4. The instrument is equipped with the highest torque measurement, reliability, along with stiff hardware, superior heater, temperature sensor, temperature controller and Vluchem’s own designed data acquisition device and software.
Mooney Viscosity
Mooney Scorch
Stress Relaxation
Model | MV-10 |
International Standard | ASTM D 1646 ISO 289 KS M ISO 289-1, 2 and 4. |
Motor | Induction Motor |
Rotor | Disk-shaped rotor |
Rotor Speed | 2 rpm |
Protection for operator | Before test chamber closing |
Test chamber moving | By Pneumatic |
Motor Platen operation | available by hardware |
Temperature control | available by hardware & |
Temperature range | microprocessor controlled |
Temp. Sensor Type | PT 100 Ω |
Torque range | 0~ 200 MU |
Temperature control |
available by hardware & |
Temperature range |
microprocessor controlled |
Temp. Sensor Type |
PT 100 Ω |
Torque range |
0~ 200 MU |
Test modes |
viscosity scorch stress relaxation Stop T5 and T3 mode |
Calibration |
Weight and software |
Data |
Initial viscosity, ML[S]1+4[N] Scorch viscosity and cure times T5(3), T35(18) and T30(15), Tmin [Multi] Stress relaxation Data files convert to excel files. Trend graphs Tolerance limits box by time and torque Average, S-Dev, ERP system upload |
Pneumatics |
min 4.5 bar/60 Psi |
Electrical |
200~230V, 3A, single phase |
Emergency Button |
|
Dimension |
W615 X D685 X H1643 mm |
Weight |
210 kgs |
Lab. Press
Useful use in laboratory
Modern Design
Heating Plate size – 300 x 300 mm
Accuracy PID Temperature control 6 different position
Digital Setting and Display system
Oil Gauge -2 different position
Remove air – automatic
Control Curing Time by digital
Reliable Products
Buzzer
4 different status lights
Emergency button
Work table for sample mold, front of instrument
Available full automatic operation and Manual operation
Technical Specification
Main Body | Powder coating |
Capacity | 50 Tons |
Heating Plate | 300 mm x 300mm |
Stroke | 200mm |
Temperature | Range RT ~ 300oC PID controller Validity ± 1oC, Digital Setting and Control |
Temp. Accuracy | ± 0.1 at 100 oC |
Timer | 6 digit |
Heating Capacity | 16kW |
Power | AC 380V, 3 phases, 50/60 HZ |
Weight | Appro. 250kgs |
Sample Cutter
Compression Set
The Vluchem’s sample cutter for MDR, and Mooney Viscometer instrument is made for safe and simple with volumetric sample cutter. This sample cutter pneumatic system allows for the preparation of uncured rubber specimens of a user-designated volume.
This sample cutter can figured for tensile test such as dumbbell type, Mooney Viscometer and rotorless rheometer which is called Moving Die Rheometer. The cutter die cut to meet volume specification per ASTM and KS standards. Sample preparation for tensile tester specimen ASTM D 412
The Vluchem’s Compression set covers the testing of rubber intended for use in applications in which the rubber will be subjected to compressive stresses in air or liquid media. They are applicable particularly to the rubber used in machinery mountings, vibration dampers, and seals.
It measures according to ASTM D 395 Test Method B, ISO 815-1.
Automatic Rubber Aging Tester/ 2nd Curing Chamber
Technical Specification
Power
220V, 50/60Hz, Single Phase
Chamber size
500 x 500 x 500 mm
Temperature Range
Maximum 300oC -Accuracy±1.0 °C
Controller
PID Control and Display
Speed
8 RPM/Min
Air Velocity
0.5m/Sec
Weight
75kgs
Automatic Freezing Point Test Chamber
This test method describes to measure the freezing point of antifreeze by rapidly decreasing the temperature from room temperature to -60°C using ethanol alcohol. 2 samples are measured simultaneously.
The following measurements may be taken from the curve of freezing versus time.
Temperature of antifreeze point
Start time of the antifreeze freezing point
-
Technical Specification
Power |
220V, 50/60 HZ, 5KW |
Motor speed |
60 ~ 80 rpm |
Coolant Circulator |
|
Temp. Range |
- 60oC ~ room temperature |
Temp. Accuracy |
± 2°C |
Temp. Prove |
Pt 100 Ω |
Data report |
Freeze point, Time, temperature, Data files convert to excel files. |
Dimension | W615 X D800 X H1700 mm |
Weight | 90 kgs |
application | windscreen wash liquid for autovehicles |
Auto IRHD Tester
The international hardness test is based on measurement of the penetration of a rigid ball
into the rubber specimen. The hardness is obtained
by the difference in penetration depth of a specified
dimension ball under conditions of contact with
a minor force and with a major force.
The differential penetration is taken at a specified
time and converted to a hardness scale value.
It’s performed according to ASTM D1415,
KS M ISO 48 and ISO 48.
The Vluchem’s IRHD-Micro is a fully automatic
instrument which is far from operator’s influences
and rubber material, polymer such as o-ring,
oil seal and various molded final goods.
AIR - 20M
Resolution - 0.1 IRHD
Min. Test Thickness - 1 mm
Data Excel Export Function
ERP System (Option)
Ce Certificatio
Test Method | IRHD Micro |
Resolution | 0.1 IRHD |
Indenter | Ø 0.397 |
Total force on ball | 153.3mN ± 1.0 |
Minor force | 8.3 mN ± 0.5 |
Major force | 145 mN ± 0.5 |
Force on foot | 235mN ± 30.0 |
Measuring range | 30 ~ 100 |
Power | 210~240V, single phase 50/60Hz |
Display | Color LCD graphic |
Data Output | Graph, Test results, Single test and multi test available |
Hardness trend graph, test results pass/fail | |
Tolerance limits, Time, Data excel export function | |
RS 232C Cable, 9600 Baud | |
Measuring Time | 30 ~ 999, Default 30 sec |
Dimension | 250 X 310 X 440 mm / 16 Kgs |
Universal Testing Machine
Vluchem electromechanical universal testing
machines perform tensile, compression as
basic test methods and other various tests are
available in accordance with the test jigs.
These instruments are available in a range
of sized and maximum force capacities.
From small, low force instruments to
test paper, rubber, plastics and film
industries, to large, high force instruments
to test metal and parts in the auto vehicle
industries and ship yard industries, Vluchem
has suitable for related applications.
It’s performed according to ASTM D412, ISO 37
and others. So many instruments have been
installed, operated in quality control,
research & development in firms and universities.
VT-200 | VT-1T | VT-10T | |
Force Capacity | 2kN | 10kN | 100kN |
Crosshead Speed | 1 ~ 750 mm/min | ||
Crosshead Stroke | 800mm or over | ||
Dimension | 500x450x1500mm | 600x550x1900mm | 700x550x1900 |
Weight | 50kg | 120kg | 150kg |
Oscillating Disk Rheometer
The Vluchem’s oscillating disk rheometer (ODR-10)
for determining selected vulcanization
characteristics of vulcanizable rubber
compounds and measured according to
ASTM D 2084, ISO 3417 and KS M 6687. ODR- 10 may be
used for quality control in rubber manufacturing
processes, for research and development testing of
raw-rubber compounded in an evaluation
formulation, and for evaluating various raw
materials used in preparing rubber compounds.
The instrument is equipped with the highest
torque measurement, reliability, along with stiff
hardware, superior heater, temperature sensor,
temperature controller and Vluchem’s own
designed data acquisition device and software.
Designed to be placed on a desk instrument
and is supplied with the Vluchem’s own data
analysis software for test management, data
recording and printing, automated Pass/Fail
testing as well as recall processing of historical
data, also available an online upload
software as an option.
Model | ODR-10 | |
International Standard | ASTM D 2084 ISO 3417 and KS M 6687 | |
Motor | Induction Motor | |
Rotor | Biconical Disk | |
Oscillation frequency | 1.67Hz | |
Oscillation angle | 1°, 3°, 5° Mechanically adjustable | |
Protection for operator | Before test chamber closing | |
Test chamber moving | By Pneumatic |
Rotor Motor Platen operation | available by hardware | |
Temperature control | available by hardware & | |
Temperature range | microprocessor controlled | |
Temp. Sensor Type | PT 100 Ω | |
Torque range | 0~ 200 dNm | |
Calibration | Calibration jig | |
Data | Torque [dNm, lbf.in] Temperature [°C] MH, ML Ts1, Ts2, Tc10(N), Tc50(N), Tc90(N) Automatic test results pass/fail function Trend graphs Tolerance limits by time and torque Data excel export function, Average, S-Dev ERP system upload - option | |
Pneumatics | min 4.5 bar/60 Psi | |
Electrical | 200~230V, 3A, single phase, 50Hz/60Hz | |
Emergency Button |
| |
Dimension | W615 X D685 X H1200 mm | |
Weight | 160 kgs |
Moving Die Rheometer
The Vluchem’s moving die rheometer (MR-10)
for determining selected vulcanization
characteristics of vulcanizable rubber
compounds using rotorless sealed
torsion meter and measured according
to ASTM D 5289,
ISO 6502-3 and KSMISO6502. MR-10 may be used for
qualitycontrol in rubber manufacturing processes,
for research and development
testing of raw-rubber compounded in an evaluation
formulation, and for evaluating various raw materials
used in preparing rubber compounds.
The instrument is equipped with the highest torque
measurement, reliability, along with stiff hardware,
superior heater, temperature sensor, temperature
controller and Vluchem’s own designed
data acquisition device and software.
Designed to be placed on a desk instrument and is
supplied with the Vluchem’s own
data analysis software for test management, data recording and printing, automated Pass/Fail testing as
well as recall processing of historical data,
also available an online upload software as an option.
Model | MR-10 |
International Standard | ASTM D 5289 ISO 6502 KS M ISO 6502 |
Motor | Induction Motor |
Die configuration | Biconical, closed die system, sealed |
Oscillation frequency | 1.67Hz |
Oscillation angle | 0.5°[Option]1°, 3°, 5° |
Protection for operator | Before test chamber closing |
Test chamber moving | By Pneumatic |
Motor Platen operation | available by hardware |
Temperature control | available by hardware & |
Temperature range | microprocessor controlled |
Temp. Sensor Type | PT 100 Ω |
Torque range | 0~ 200 dNm |
Calibration | Calibration jig |
Data | Torque[dNm, lbf.in] Temperature [°C] MH, ML Ts1, Ts2, Tc10(N), Tc50(N), Tc90(N) Automatic test results pass/fail function Trend graphs Tolerance limits by time and torque Data excel export function, Average, S-Dev |
Pneumatics | min 4.5 bar/60 Psi |
Electrical | 200~230V, 3A, single phase, 50Hz/60Hz |
Emergency Button |
|
Dimension | W615 X D685 X H1200 mm |
Weight | 160 kgs |
Auto Moving Die Rheometer
The Vluchem’s automatic moving die rheometer
(AMR-10) for determining selected vulcanization
characteristics of vulcanizable rubber compounds
using rotorless sealed torsion meter and measured
according to ASTM D 5289, ISO 6502-3 and KSMISO6502.
MR-10 may be used for quality control in rubber
manufacturing processes, for research and
development testing of raw-rubber compounded in an
evaluation formulation, and for evaluating various raw
materials used in preparing rubber compounds.
The instrument is equipped with the highest torque
measurement, reliability, along with stiff hardware,
superior heater, temperature sensor, temperature
controller and Vluchem’s own designed data
acquisition device and software.
Designed to be placed on a desk instrument and is
supplied with the Vluchem’s own data analysis
software for test management, data recording and
printing, automated Pass/Fail testing as well as recall
processing of historical data, also available an online
upload software as an option.
Automatic Sample supply device
Model | AMR-10 | |
International Standard | ASTM D 5289 ISO 6502 KS M ISO 6502 | |
Motor | Induction Motor | |
Die configuration | Biconical, closed die system, sealed | |
Oscillation frequency | 1.67Hz | |
Oscillation angle | 0.5°[Option]1°, 3°, 5° | |
Protection for operator | Before test chamber closing | |
Test chamber moving | By Pneumatic |
Motor Platen operation | available by hardware | ||
Temperature control | available by hardware & | ||
Temperature range | microprocessor controlled | ||
Temp. Sensor Type | PT 100 Ω | ||
Torque range | 0~ 200 dNm | ||
Calibration | Calibration jig | ||
Data | Torque[dNm, lbf.in] Temperature [°C] MH, ML Ts1, Ts2, Tc10(N), Tc50(N), Tc90(N) Data excel export function, Trend graphs Tolerance limits by time and torque Average, S-Dev | ||
Pneumatics | min 4.5 bar/60 Psi | ||
Electrical | 200~230V, 3A, single phase, 50Hz/60Hz | ||
Emergency Button |
| ||
Dimension | W1200 X D685 X H1200 mm | ||
Weight | 180 kgs | ||
Linear Automation | AMR-10 [5 samples] |
Mooney Viscometer
The Vluchem’s Mooney Viscometer (MV-10) which
measures the Mooney viscosity is defined as the
shearing torque resisting rotation of a rotor embedded
in rubber within a cylindrical cavity. At the end of a
Mooney viscosity test, the rotation of the rotor is
suddenly stopped and the rate of decrease of
torque is monitored as a function of time. This is called
stress relaxation. Characteristics of uncompounded or
compounded rubbers and measured according to
ASTM D 1646, ISO 289, KSMISO 289-1, 2 and 4.
Mooney Viscosity
Mooney Scorch
Stress Relaxation
Model | MV-10 |
International Standard | ASTM D 1646 ISO 289 KS M ISO 289-1, 2 and 4. |
Motor | Induction Motor |
Rotor | Disk-shaped rotor |
Rotor Speed | 2 rpm |
Protection for operator | Before test chamber closing |
Test chamber moving | By Pneumatic |
Motor Platen operation | available by hardware |
Temperature control | available by hardware & |
Temperature range | microprocessor controlled |
Temp. Sensor Type | PT 100 Ω |
Torque range | 0~ 200 MU |
Temperature control | available by hardware & |
Temperature range | microprocessor controlled |
Temp. Sensor Type | PT 100 Ω |
Torque range | 0~ 200 MU |
Test modes | viscosity scorch stress relaxation Stop T5 and T3 mode |
Calibration | Weight and software |
Data | Initial viscosity, ML[S]1+4[N] Scorch viscosity and cure times T5(3), T35(18) and T30(15), Tmin [Multi] Stress relaxation Data files convert to excel files. Trend graphs Tolerance limits box by time and torque Average, S-Dev, ERP system upload |
Pneumatics | min 4.5 bar/60 Psi |
Electrical | 200~230V, 3A, single phase |
Emergency Button |
|
Dimension | W615 X D685 X H1643 mm |
Weight | 210 kgs |
Lab. Press
Useful use in laboratory
Modern Design
Heating Plate size – 300 x 300 mm
Accuracy PID Temperature control
6 different position
Digital Setting and Display system
Oil Gauge -2 different position
Remove air – automatic
Control Curing Time by digital
Reliable Products
Buzzer
4 different status lights
Emergency button
Work table for sample mold, front of instrument
Available full automatic operation and Manual
operation
Technical Specification
Main Body Powder coating
Capacity 50 Tons
Heating Plate 300 mm x 300mm
Stroke 200mm
Temperature Range RT ~ 300oC PID controller
Validity ± 1oC, Digital Setting and Control
Temp. Accuracy ± 0.1 at 100 oC
Timer 6 digit
Heating Capacity 16kW
Power AC 380V, 3 phases, 50/60 HZ
Weight Appro. 250kgs
Sample Cutter
Compression Set
The Vluchem’s sample cutter for MDR, and Mooney
Viscometer instrument is made for safe and simple
with volumetric sample cutter. This sample cutter
pneumatic system allows for the preparation of
uncured rubber specimens of a user-designated
volume. This sample cutter can figured for tensile
test such as dumbbell type, Mooney Viscometer
and rotorless rheometer which is called
Moving Die Rheometer.
The cutter die cut to meet volume
specification per ASTM and KS standards. Sample
preparation for tensile tester specimen ASTM D 412
Compression Set
Automatic Rubber Aging Tester
/ 2nd Curing Chamber
The Vluchem’s test chamber is a device that
accelerates aging in a chamber with prescribed
conditions to observe the aging of rubber over
time in the natural state and observes
the change state.
Technical Specification
Power
220V, 50/60Hz, Single Phase
Chamber size
500 x 500 x 500 mm
Temperature Range
Maximum 300oC -Accuracy±1.0 °C
Controller
PID Control and Display
Speed
8 RPM/Min
Air Velocity
0.5m/Sec
Weight
75kgs
Automatic Freezing Point Test Chamber
This test method describes to measure the freezing point of antifreeze by rapidly decreasing the
temperature from room temperature to
-60°C using ethanol alcohol. 2 samples are
measured simultaneously.
The following measurements may be taken
from the curve of freezing versus time.
Temperature of antifreeze point
Start time of the antifreeze freezing point
Technical Specification
Power | 220V, 50/60 HZ, 5KW |
Motor speed | 60 ~ 80 rpm |
Coolant Circulator | |
Temp. Range | - 60oC ~ room temperature |
Temp. Accuracy | ± 2°C |
Temp. Prove | Pt 100 Ω |
Data report | Freeze point, Time, temperature, Data files convert to excel files. |
Dimension | W615 X D800 X H1700 mm |
Weight | 90 kgs |
application | windscreen wash liquid for autovehicles |
You will receive a password change notification email at the email address for your account.